Panels & service upgrades
PermitLoad calculation, new panel and main breaker, grounding and bonding brought to current code, every circuit labeled. Utility coordination for the disconnect and reconnect. Power is off most of the day.
Panels, EV chargers, generators, rewiring. Pick the job, tell us the house, and you'll know before we call whether it needs a permit, what the visit looks like, and what we'll want to see. Then we put it in writing.
Some of these are today problems. Some can wait for a planned visit. Here's how we'd triage them if you called.
Once is a nuisance. Repeatedly on the same circuit means overload, a failing breaker, or a fault in the wiring.
Call todayHeat at a cover plate is resistance somewhere behind it: a loose connection, a backstabbed wire, or a worn device.
Call todayA little flicker on a big motor start can be normal. Every time, across the house, points to a loaded panel or a loose neutral.
Schedule this monthA panel should be silent. Buzzing is arcing or a breaker that isn't seated. Don't open the cover; call.
Call todayNo ground path. Not an emergency, but a real limit on what you can plug in safely. Fixable room by room or as part of a rewire.
Plan itCommon in homes wired 1965–1973. Connections loosen over time. We can test and repair with approved connectors, or plan a rewire.
Schedule this monthResidential only. Every job below gets a written scope before a tool comes off the truck.
Load calculation, new panel and main breaker, grounding and bonding brought to current code, every circuit labeled. Utility coordination for the disconnect and reconnect. Power is off most of the day.
A dedicated 240V circuit sized to the charger, run from the panel to the garage or driveway. Hardwired or a 14-50 receptacle. Load calc first; load management if the panel is tight.
Standby units on a pad with automatic transfer, or a manual transfer switch or interlock for a portable. We coordinate the gas side and the inspection.
Replacing knob-and-tube, cloth, or aluminum wiring; adding kitchen, bath, or workshop circuits; grounding two-prong rooms. Fished through walls where possible, patched where not.
Recessed and under-cabinet lighting, exterior and landscape lighting, ceiling fans on a rated box, dimmers matched to the bulbs. New circuits need a permit; a fixture swap doesn't.
Dead circuits, tripping breakers, GFCI and AFCI nuisance trips, outlets that stopped working. We find the cause, show you, and fix it or write it up.
A permit isn't red tape. It's a second set of eyes on work that lives inside your walls for decades.
Both start with the same question: what does your panel have room for? Here's what each needs so the quote makes sense when you read it.
Typical visit: half a day when the panel has capacity. A full day if the panel is upgraded the same trip.
Permanent unit on a pad, runs on natural gas or propane, starts itself within seconds of an outage through an automatic transfer switch. Whole-house or essential-circuits sizing.
You roll it out, plug into an inlet on the house, and flip a manual transfer switch or interlock. Powers the circuits you chose ahead of time: furnace, fridge, sump, a few lights.
Never plug a generator into a dryer outlet or run cords through a window. A transfer switch is what keeps your power from feeding back into the lines a utility crew is working on. Typical install: one to two days plus gas and inspection coordination.
The same sequence whether it's one circuit or a whole-house rewire. You'll always know which step you're on.
We look at the panel, the route the wire has to take, and the house's age and wiring type. Bring your questions.
What we'll do, what materials, what's included in the permit, and what could change it. You approve before anything is scheduled.
We file with the building department and, for panel work, schedule the utility disconnect. You get the permit number.
We tell you how long power will be off and protect the floors on the way in. Any surprise inside a wall gets a call, not a bill.
The inspector signs off. If they want something adjusted, that's on us, not you.
We show you what changed, how the labels read, and what to do if a breaker trips. Panel directory goes on the door.
Trucks run from the north side of Fort Wayne. We stay inside roughly a thirty-minute drive so a two-visit job (rough-in, then final) doesn't cost you a week of waiting.
Auburn, Churubusco, or Ossian? Ask. For panel and generator projects we'll usually come.
Something sparking or smoking right now? Skip the form. (260) 555-0144